BTS9000 is the most advanced battery testing instrument from Neware, it's the best choice for material research, but some customers think BTS9000 is a little expensive. Thus, we developed BTS9000-2CH for people who want to get high accuracy and high speed with low price.

The only performance difference between BTS9000-2CH and BTS9000-4CH is that: the 2 channels of BTS9000-2CH can't perform pulse test simultaneously.

So if you need all channels to do the pulse tests together, then BTS9000-4CH is the right choice, or else BTS9000-2CH is the better one. You can tell from the below table that BTS9000-2CH is just as great as BTS9000-4CH in all the main features.

BTS9000-2Ch got all the key features you need:

  • 2 channels
  • 0.02%FS accuracy
  • 1000Hz data acquisition frequency
  • Min pulse width 400us
  • Slim design, space-saving
 
BTS9000-4CH
BTS9000-2CH
Channels
4
2
Accuracy
0.02%FS
0.02%FS
Pulse test
Yes
Yes
Simultaneous pulse test
Yes
No
Min pulse width
400us
400us
Offline mode
Yes
Yes
Data acquisition frequency
1000Hz
1000Hz
Offline data storage
64GB
16GB
Output socket position
Rear panel
Front panel
Dimension
57cm*58cm*13cm
45cm*35cm*4.5cm(slim design)
Price
$$,$$$USD
$,$$$USD
    This email address is being protected from spambots. You need JavaScript enabled to view it.

 BTS9000-2CH

Need the detailed specifications of BTS9000-2CH, here it is!

specifications of BTS9000-2CH

Download the specifications of BTS9000-2CH.

As the most advanced battery testing system from Neware, BTS9000 is capable of all the popular pulse tests, such as GSM/CDMA/GPRS/WCDMA, etc.
Following pictures are the screenshots from Agilent oscilloscope, these pictures show that BTS9000 output pulse curves exactly as cutomers' requirement.
It the ideal choice for battery material research.
BTS9000-pulse-output

BTS9000-pulse-output

BTS9000-pulse-output

BTS9000:The Most Cutting-edge equipment for Battery Material Research

BTS9000 - advanced battery testing systemBTS9000 is based on Neware 6th-generation testing system. It's designed for battery material research, high-precision tests, pulse charge/discharge tests, DCIR test, and cycle life test.
As the most cutting-edge equipment for battery material research, BTS9000 comes with extremely high accuracy(±0.02% of FS), amazing hardware response speed(≤100μs), wide range of applications, high-speed testing data acquisition and many other industry-proven characteristics, it's your ultimate choice for battery material research!
Comes to the pulse tests, BTS9000 supports GSM(Global System for Mobile Communications), GPRS(General Packet Radio Service), CDMA-standby, CDMA-talk(Code Division Multiple Access), IDEN(Integrated Digital Enhanced Networks), etc. It characterized with a data acquisition frequency up to 1000Hz, an accuracy of 0.02% FS and a minimum pulse width of 400us (microsecond) which can be utilized for GSM or some other rapid pulse tests.

1. FEATURES AND FUNCTIONS

Extremely high accuracy(±0.02% of FS)
Hardware Response Time: ≤100μs
Min pulse width: 400μs
Adaptable to a wide range of products (cells, batteries, super-capacitors and battery modules, etc.)
Wide range of applications (grading, over charging/discharging, ladder-type charge/discharge, pulse)
DCIR, HPPC and GSM Pulse tests supported
4 channels paralleled available(not available, noted on 12.12.2015)
Multi-current range available(4 ranges per channel)
Every channel can be user programmed to operate in steps of CCC(Constant Current Charging), CVC(Constant Voltage Charging), CC&CVC(Constant Current & Constant Voltage Charging), CPC(Constant Power Charging), CCD(Constant Current Discharging), CPD(Constant Power Discharging), Pulse, DCIR, etc.
Completely independent channels allow users to run multiple independent tests simultaneously without affecting other channels
With the BTS client software, data is easily viewed graphically
Diverse alligators and probe connection accessories for choose

2. HARDWARE SPECIFICATIONS

Input Power: AC 220V ±10% 50Hz
Voltage Output Range: 0 - 5V
Resolution: AD(16bit); DA(16bit)
Control Accuracy: ±0.02% of FS
Measuring Accuracy: ±0.02% of FS
Hardware Response Time: ≤100μs (10%-90% Current)
Data recording rate: up to 1000Hz, △T/△U/△I
Operating modes: Charge - CC(Constant Current),CV(Constant Voltage), CC&CV(Constant Current & Constant Voltage), CP(Constant Power), Pulse
Discharge- CC(Constant Current), CV(Constant Voltage), CR(Constant Resistance), CP(Constant Power), Pulse
Min pulse width: 400μs
Multi range: Each channel supports 4 ranges