CE-4008-10V10A-SR
Specification

Tester Model
ParameterData
Model CodeCE-4008-10V10A-SR
Item Parameters
ParameterData
Input Power SupplyAC 220V ±10% / 50Hz
Input Power1200 W
Resolution (AD / DA)AD: 24-bit; DA: 16-bit
Impedance≥ 1 MΩ
Energy Recovery Efficiency> 70%
Noise (full load)< 75 dB (measured within 1 m)
Parallel FunctionUp to 8 channels in parallel (pulse testing not supported when paralleled)
IP Protection RatingIP20
Channel FeaturesCC & CV sources with dual closed-loop control
Channel ControlEach channel independent
Voltage & Current SamplingKelvin connection
Voltage
ParameterData
Range50 mV – 10 V
Minimum Discharge Voltage2 V (using 2 m wire)
Accuracy± 0.02% of FS
Precision0.04% of FS
Current
ParameterData
Range10 A
Minimum Output Current0.5% of FS
Accuracy± 0.05% of FS
Minimum CV Cut-off Current0.2% of FS
Precision0.1% of FS
Power
ParameterData
Maximum Output Power (Single Channel)100 W
Accuracy± 0.07% of FS
Precision0.14% of FS
System Operation Time
ParameterData
Current Rising Time (10%→90% FS)≤ 1 ms
Charge/Discharge Shifting Time (−90%→90% FS)≤ 10 ms
Step Time≤ (365×24) h per step; format 00:00:00.000
Sampling Rate10 Hz (minimum interval 100 ms)
Step Modes
ParameterData
Charging & Discharging ModesCC, CV, CCCV, CP, Pulse, CR, Follow Steps
Cut-off ConditionsVoltage, Time, Step time, Capacity, Energy, −△V, Customized variable
DCIR TestCustom sampling points for DCIR calculation
Pulse TypesCC, CP
Minimum Pulse Width100 ms
Number of PulsesSingle pulse step supports 32 different pulses
Pulse ShiftContinuous switching of charging or of discharging within a pulse step
Pulse Cut-off ConditionsVoltage, Step time
Cycle
ParameterData
Cycle Ranges1 – 65535
Steps per Cycle≤ 255
Layers of Cycles< 10
Protection System
ParameterData
Software ProtectionPower-off data protection; offline testing; configurable safety limits (V/I upper & lower, capacity, delay, custom variables…)
Hardware ProtectionReverse polarity, OVP, OCP, OTP, emergency stop, etc.
Computer Requirements
ParameterData
CPUPentium dual-core or above, ≥ 4 GHz
RAM16 GB
Disk500 GB
Operating SystemWindows 7
CommunicationTCP/IP
DatabaseMySQL
Data Export FormatsEXCEL, TXT, GRAPH, PDF, CSV
COM (Optional)CAN, RS485 & BMS, DBC
Environmental Requirements
ParameterData
Working Temperature0–40 ℃ (within 25 ±10 ℃ to ensure 0.05% of FS/℃; drift 0.005% of FS/℃)
Storage Temperature−10–50 ℃
Working Humidity≤ 70% RH (no condensation)
Storage Humidity≤ 80% RH (no condensation)
Fixtures
ParameterData
Channels on One Unit8
Fixture TypeDepends on requirement (e.g., crocodile clip for wires, pouch cell clip, ring lug)