CE-4008-10V10A-SR
Specification
Tester Model
| Parameter | Data |
|---|---|
| Model Code | CE-4008-10V10A-SR |
Item Parameters
| Parameter | Data |
|---|---|
| Input Power Supply | AC 220V ±10% / 50Hz |
| Input Power | 1200 W |
| Resolution (AD / DA) | AD: 24-bit; DA: 16-bit |
| Impedance | ≥ 1 MΩ |
| Energy Recovery Efficiency | > 70% |
| Noise (full load) | < 75 dB (measured within 1 m) |
| Parallel Function | Up to 8 channels in parallel (pulse testing not supported when paralleled) |
| IP Protection Rating | IP20 |
| Channel Features | CC & CV sources with dual closed-loop control |
| Channel Control | Each channel independent |
| Voltage & Current Sampling | Kelvin connection |
Voltage
| Parameter | Data |
|---|---|
| Range | 50 mV – 10 V |
| Minimum Discharge Voltage | 2 V (using 2 m wire) |
| Accuracy | ± 0.02% of FS |
| Precision | 0.04% of FS |
Current
| Parameter | Data |
|---|---|
| Range | 10 A |
| Minimum Output Current | 0.5% of FS |
| Accuracy | ± 0.05% of FS |
| Minimum CV Cut-off Current | 0.2% of FS |
| Precision | 0.1% of FS |
Power
| Parameter | Data |
|---|---|
| Maximum Output Power (Single Channel) | 100 W |
| Accuracy | ± 0.07% of FS |
| Precision | 0.14% of FS |
System Operation Time
| Parameter | Data |
|---|---|
| Current Rising Time (10%→90% FS) | ≤ 1 ms |
| Charge/Discharge Shifting Time (−90%→90% FS) | ≤ 10 ms |
| Step Time | ≤ (365×24) h per step; format 00:00:00.000 |
| Sampling Rate | 10 Hz (minimum interval 100 ms) |
Step Modes
| Parameter | Data |
|---|---|
| Charging & Discharging Modes | CC, CV, CCCV, CP, Pulse, CR, Follow Steps |
| Cut-off Conditions | Voltage, Time, Step time, Capacity, Energy, −△V, Customized variable |
| DCIR Test | Custom sampling points for DCIR calculation |
| Pulse Types | CC, CP |
| Minimum Pulse Width | 100 ms |
| Number of Pulses | Single pulse step supports 32 different pulses |
| Pulse Shift | Continuous switching of charging or of discharging within a pulse step |
| Pulse Cut-off Conditions | Voltage, Step time |
Cycle
| Parameter | Data |
|---|---|
| Cycle Ranges | 1 – 65535 |
| Steps per Cycle | ≤ 255 |
| Layers of Cycles | < 10 |
Protection System
| Parameter | Data |
|---|---|
| Software Protection | Power-off data protection; offline testing; configurable safety limits (V/I upper & lower, capacity, delay, custom variables…) |
| Hardware Protection | Reverse polarity, OVP, OCP, OTP, emergency stop, etc. |
Computer Requirements
| Parameter | Data |
|---|---|
| CPU | Pentium dual-core or above, ≥ 4 GHz |
| RAM | 16 GB |
| Disk | 500 GB |
| Operating System | Windows 7 |
| Communication | TCP/IP |
| Database | MySQL |
| Data Export Formats | EXCEL, TXT, GRAPH, PDF, CSV |
| COM (Optional) | CAN, RS485 & BMS, DBC |
Environmental Requirements
| Parameter | Data |
|---|---|
| Working Temperature | 0–40 ℃ (within 25 ±10 ℃ to ensure 0.05% of FS/℃; drift 0.005% of FS/℃) |
| Storage Temperature | −10–50 ℃ |
| Working Humidity | ≤ 70% RH (no condensation) |
| Storage Humidity | ≤ 80% RH (no condensation) |
Fixtures
| Parameter | Data |
|---|---|
| Channels on One Unit | 8 |
| Fixture Type | Depends on requirement (e.g., crocodile clip for wires, pouch cell clip, ring lug) |