Neware high low temperature test chambers are available in a variety of configurations that can meet your specific temperature, humidity, and safety protection requirements. The high low temperature test chamber aims to test the performance of batteries under simulated harsh climate conditions, which can provide a good reference for the researchers and engineers at the product design and development stage.
All Neware environmental test chambers can connect with our battery testing system on the same software within the same working profile and make your testing process way much easier!
Model Customization
Product Code (Example) |
MGDW | – | 225 | – | 40 | – | H | – | B | – | F | – | C |
Description | Highest Temp. | Volume | Lowest Temp. | Add-on Function | Cooling Method | ||||||||
Custom Selection |
150°C | 150L | [70]: -70°C
or [40]: -40°C or [20]: -20°C |
[/]: Default
or [H]:Humidity |
[/]: Default or [B]:Explosion Proof |
[/]: Default or [F]:Fire Extinguisher |
[/]: Default (single-stage vapour compression refrigeration) or [C]: Cascade Refrigeration System |
||||||
225L | |||||||||||||
408L | |||||||||||||
800L | |||||||||||||
1000L |
Popular Choices:
Dimension
Chamber | Volume | Unit Inner Dimension | Chamber Outer Dimension | ||||
W(mm) | D(mm) | H(mm) | W(mm) | D(mm) | H(mm) | ||
Single Layer | |||||||
150L | 500 | 500 | 600 | 750 | 1350 | 1600 | |
225L | 600 | 500 | 750 | 850 | 1350 | 1750 | |
408L | 800 | 600 | 850 | 1050 | 1450 | 1850 | |
800L | 1000 | 800 | 1000 | 1250 | 1650 | 2000 | |
1000L | 1000 | 1000 | 1000 | 1250 | 1850 | 2000 | |
Double Layer | 150L *2 | 500 | 500 | 600 | 1100 | 2000 | 2000 |
225L*2 | 600 | 500 | 750 | 1200 | 2000 | 2050 |
Performance
Temperature Range: -70°C / -40°C / -20°C ~ 150°
Deviation: ±2.0℃
Fluctuation: ≤1℃
Heating Time: +20℃ →+150℃ ≤60 min
Cooling Time (-20℃): +20℃ →-20℃ ≤45 min
Cooling Time (-40℃): +20℃ →-40℃ ≤60 min
Cooling Time (-70℃): +20℃ →-70℃ ≤75 min
Humidity Control Space:
Health and Safety Protection
Short-circuit protection
Over-temperature protection
Fume extraction (with alarm)
Automatic fire extinguisher
Conditions of Use
Room Temperature: 5~35°C
Relative Humidity: ≤ 85%
Atmosphere Pressure: 86kPa~106kPa
Level Ground: Comply with GB50209-2002 Specification
Flatness: ≤ 5mm/2m
Electromagnetic: No strong electromagnetic fields around the device
Vibration: No strong vibration around the device
Bizards: No flammable/explosive/corrosive substances & dust around the device
Space: Appropriate space (≥ 600 mm) for use and maintenance