NEWARE BATTERY MATERIALS RESEACH SOLUTIONS
Neware provides tailored testing solutions for battery materials researchers across universities, public research organizations, and corporate R&D centers, integrating high-precision electrochemical analysis to comprehensively validate material performance and accelerate R&D progression—from fundamental material screening to application-oriented evaluation.
Supported Electrochemical Measurement Capabilities
Beyond Standard Charge–Discharge Testing
Cyclic Voltammetry(CV)
Precision, from the smallest to the strongest.
With voltage and current accuracy up to 0.01%, NEWARE Cyclers enable CV testing from ultra-low currents of 0.2 μA to peak currents of 100 mA.
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- Cyclic Voltammetry(CV) Supported
Learn more about this model >
- Voltage Range: -5V-5V
- Current Range: 180uA/6mA/180mA/6A
- Voltage & Current Accuracy: ± 0.02% of F.S.
- Cyclic Voltammetry(CV) Supported
Learn more about this model >
Electrochemical Impedance Spectroscopy(EIS)
Unlock impedance, at every frequency.
NEWARE Cyclers enable EIS testing across a wide frequency range from 0.01 Hz to 100 kHz, providing detailed insights into electrochemical behavior and enabling precise equivalent circuit modeling.
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- Current Accuracy: ± 0.01% of F.S.
Learn more about this model >
Potentiostatic and Galvanostatic Techniques
Seamless, from start to finish.
With a −5 V to +5 V output range and <20 μs current response, it enables fast, stable regulation and seamless mode switching for uninterrupted electrochemical measurements.
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- Galvanostatic (CC) and Potentiostatic (CV) Control Modes Supported
Learn more about this model >
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- Galvanostatic (CC) and Potentiostatic (CV) Control Modes Supported
Learn more about this model >
Galvanostatic Intermittent Titration Technique(GITT)
See every millivolt clearly, at every moment.
A 24-bit ADC combined with a <20 µs current conversion time enables fast, stable control and accurate voltage measurement for advanced electrochemical techniques such as GITT.
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- GITT Supported
Learn more about this model >
- Voltage Range: -5V-5V
- Current Range: 0.1mA/1mA/5mA/10mA/50mA/100mA
- Voltage & Current Accuracy: ± 0.01% of F.S.
- GITT Supported
Learn more about this model >
Where Battery Materials Research Meets Real Challenges
Cycle Life
RFBs are designed for ultra-long cycling, with lifetime tests extending to tens of thousands of operating hours.
Such prolonged testing places stringent demands on system stability, continuity, and data integrity over time.
Built to Support Uninterrupted Long-Term Cycling
Neware 4000 series is built to support uninterrupted long-term cycling by design.
• Dual-layer data protection with MySQL database and automatic backup
All test data are continuously written to a MySQL database to prevent data loss during power failures or unexpected interruptions.
In addition, an automatic backup function allows users to configure backup intervals and target paths, enabling test results to be periodically archived for long-term data security during ultra-long cycling tests.
• Ultra-long test execution without artificial limits
A single working step can run continuously for up to one year, with support for up to 65,535 cycles, eliminating the need to split long-term cycling tests into multiple segments.
Rate Capability
High-power LFP batteries and supercapacitors are designed for high-rate operation, with charge and discharge tests covering an exceptionally wide current range.
Such extreme rate conditions place stringent requirements on current accuracy, measurement stability, and automatic range switching.
Built to Support Uninterrupted Long-Term Cycling
CT-8002S-5V100mA is built to support uninterrupted long-term cycling by design.
Neware systems are designed to support reliable rate capability testing under wide current conditions.
• Up to six current ranges with automatic switching
Six automatically switching current ranges cover low to high rate conditions, ensuring consistent current accuracy across a wide operating range during rate capability testing.
• ±0.01% current accuracy within each range
Within every measurement range, current accuracy is maintained at ±0.01%, enabling consistent rate performance evaluation
Temperature Performance
Sodium-ion batteries have gained market traction with strong low-temperature performance, while solid-state batteries still face temperature-related challenges. Faster and more efficient development is essential to shorten the path from the laboratory to real-world applications.
Built to Support Uninterrupted Long-Term Cycling
Neware 4000 series is built to support uninterrupted long-term cycling by design.
• Wide temperature range from –70 °C to +150 °C
Neware test systems support an ultra-wide operating temperature range from –70 °C to +150 °C, enabling comprehensive evaluation of battery performance under extreme low- and high-temperature conditions.
• Parallel testing across multiple temperature zones
Multiple temperature zones can operate simultaneously, allowing different temperature conditions to be tested in parallel and significantly improving test efficiency during rapid development cycles.
Energy Density
High-energy-density systems such as silicon-carbon anodes and solid-state batteries are highly sensitive to interfacial stability and impedance evolution during cycling. Such interface-driven performance changes make EIS a critical analytical tool for identifying and quantifying the evolution of interfacial resistance.
Built to Support Uninterrupted Long-Term Cycling
Neware 4000 series is built to support uninterrupted long-term cycling by design.
Wide temperature range from –70 °C to +150 °C
Neware test systems support an ultra-wide operating temperature range from –70 °C to +150 °C, enabling comprehensive evaluation of battery performance under extreme low- and high-temperature conditions.
Parallel testing across multiple temperature zones
Multiple temperature zones can operate simultaneously, allowing different temperature conditions to be tested in parallel and significantly improving test efficiency during rapid development cycles.
Why Neware for Battery Materials Research
From Materials Research to Scalable Validation
Neware’s testing systems span the entire workflow from battery materials research and cell validation to scale-up testing, minimizing the risk of data discontinuity across R&D stages, reducing redundant validation, and accelerating research efficiency and product iteration.
Flexible Expansion for Multi-Parameter Testing
Neware’s testing systems allow flexible integration of auxiliary channels for voltage, temperature, and pressure monitoring, supporting multi-parameter testing and smooth system expansion throughout different stages of battery research and validation.
Powerful and User-Friendly Data Analysis Software
Neware’s software features an intuitive interface and flexible data analysis tools, enabling users to define custom curves, configure axes freely, and export test data in common formats such as Excel, TXT, and CSV for efficient post-processing and collaboration.
High-Precision Measurement for Reproducible Results
Neware’s testing systems leverage industry-leading resolution, precision, and accuracy to deliver stable and highly reproducible data. Over the past 27 years, our systems have been adopted by over 90% of the world’s leading universities and research institutions.
What Can Be Tested with Neware Systems
Supported Cell Formats and Test Configurations
- Coin cells
- Pouch cells
- Cylindrical cells
- Prismatic cells
- Three-electrode testing system
- Custom-shaped cells
Supported Battery Chemistries
- Sodium-ion batteries
- Silicon-based anode systems
- Solid-state batteries
- Lithium–sulfur (Li–S) and lithium–air (Li–Air) batteries
- High-voltage electrolyte systems
- High-nickel cathode materials
Applicable Cell Formats
- CR2032
- CR2025
- CR2016
- Other CR formats
Operating Instructions
- Red terminal = Positive (+)
- Black terminal = Negative (−)
- Ensure correct polarity before operation
Supported Applications
- Pouch cells
- Batteries with leads
- Three-electrode testing
Four-wire (Kelvin) connection leads
- I+ (Current Positive) – Red
- I− (Current Negative) – Black
- V+ (Voltage Positive) – Orange
- V− (Voltage Negative) – Gray
Applicable Cell Formats
- Semi-solid-state batteries
- All-solid-state batteries
Key Features
- Built-in pressure sensor for real-time pressure monitoring
- Compatible with Constant Temperature Chamber and High and Low Tmeprature Chamber
What Makes Neware Innovative
Self-Discharge Tester
From Waiting for Voltage Drop to Measuring Leakage Directly.
All-in-One Testing System
No Cables. No Clutter. No Complexity.
Four-Zone Temperature Testing System
One Test. Four Temperatures. Zero Time Waste.