Amp-Level Battery Cycler
5V 20A/30A
5V 1A/3A/6A/12A/15A
5V 5A/6.5A/12A/15A
BTS-4000 Amp-Level Battery Cycler
Key Features
High Accuracy
The system provides both voltage and current measurement and control accuracy of ±0.02%~±0.05%, ensuring stable and reliable charge and discharge performance across the full operating range.
Accurate control of both voltage and current reduces systematic measurement deviations and improves data repeatability, which is essential for quantitative electrochemical analysis and long-term cycling tests.
Multi-range
The system is designed with multiple current ranges, each optimized for measurement accuracy within its specific operating range.
By automatically selecting appropriate current ranges, the tester maintains accurate current control and measurement from low-current conditions to full-scale operation. This ensures reliable test results across different current magnitudes while improving the overall versatility of the equipment for a wide range of battery testing applications.
High Sampling Rate
With a sampling rate of up to 100 Hz, the system captures transient voltage and current responses during dynamic charge and discharge processes.
This allows more detailed analysis of short-term electrochemical behavior, such as polarization effects and rapid current changes, which may be missed at lower sampling rates.
Durable
The equipment is designed for long-term stability and supports continuous operation exceeding 10,000 hours.
This reliability is particularly important for extended cycling tests, aging studies, and long-duration experiments where uninterrupted operation and data continuity are critical.
Browse by Range
CT-4008Q-5V6A-S1-W
- Voltage Range: ±5V
- Current Range: 100mA/500mA/3A/6A
- Voltage & Current Accuracy: ±0.02% F.S.
- Minimum Discharge Voltage: 1.5V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Discharge Resistor
CT-4008Q-5V6A-S1-F-W
- Voltage Range: ±5V
- Current Range: 0.1mA/1mA/10mA/50mA
- Voltage & Current Accuracy: ±0.02% F.S.
- Minimum Discharge Voltage: 0V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Discharge Resistor
CT-4008Tn-5V12A-S1-F
- Voltage Range: ±5V
- Current Range: 1mA/6A/12A
- Voltage & Current Accuracy: ±0.02% F.S.
- Minimum Discharge Voltage: 0V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Discharge Resistor
CE-4008Q-5V15A-S1
- Voltage Range: ±5V
- Current Range: 300mA/3A/6A/15A
- Voltage & Current Accuracy: ±0.05% F.S.
- Minimum Discharge Voltage: 1.5V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Regenerative Discharge
CE-4008S-5V20A-SR
- Voltage Range: ±5V
- Current Range (Six Ranges): 300mA/1A/3A/6A/12A/20A
- Voltage & Current Accuracy: ±0.02% F.S.
- Minimum Discharge Voltage: 1.5V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Regenerative Discharge
- Current parallel up to 160A
CE-4008Q-5V30A-SR
- Voltage Range: ±5V
- Current Range: 1A/6A/12A/30A
- Voltage & Current Accuracy: ±0.05% F.S.
- Minimum Discharge Voltage: 1.5V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Regenerative Discharge
Not sure which product is the best fit? Contact expert for professional solution
BTS-9000 Amp-Level Battery Cycler
Key Features
High Accuracy & Precision
The system provides voltage and current measurement accuracy of up to ±0.02%, with measurement precision better than 0.01%.
High accuracy and precision are essential for minimizing measurement uncertainty and ensuring consistent, repeatable results in long-term cycling tests and low-current electrochemical measurements.
1000Hz Sampling Rate
A sampling rate of up to 1000 Hz enables high-resolution acquisition of voltage and current signals during battery testing.
This allows detailed observation of fast transient behavior and dynamic responses that may not be captured at lower sampling rates.
µs-level Current Response
The system achieves a current response time of 100 µs, allowing rapid transition and stabilization to the target current level.
Fast current response is critical for accurately reproducing transient test conditions and ensuring precise current control in pulse and dynamic battery tests.
<1ms Pulse Capability
The tester supports short-duration current pulses with a minimum pulse width of 400 µs.
This capability is important for pulse-based testing methods, such as internal resistance evaluation and short-time electrochemical response analysis.
Browse by Range
CT-9004-5V5A-G4T
- Voltage Range: ±5V
- Current Range: 150µA/5mA/150mA/5A
- Voltage & Current Accuracy: ±0.02% F.S.
- Voltage & Current Precision: ±0.005% F.S.
- Minimum Discharge Voltage: -5V
- Recording Frequency: 1000Hz
- Sampling Time: 1ms
- Current Response Time: ≤100µs
- Off-Line Test: 1GB
- Discharge Resistor
- Thermal Detector Included
CT-9004-5V6.5A-GSM
- Voltage Range: ±5V
- Current Range: 195µA/6.5mA/195mA/6.5A
- Voltage & Current Accuracy: ±0.02% F.S.
- Voltage & Current Precision: ±0.01% F.S.
- Minimum Discharge Voltage: 0.7V
- Recording Frequency: 1000Hz
- Sampling Time: 1ms
- Current Response Time: ≤100µs
- Off-Line Test: 1GB
- Discharge Resistor
- Minimum Pulse Width: 400μs
CT-9008-5V12A-T-SMB
- Voltage Range: ±5V
- Current Range: 300µA/10mA/300mA/12A
- Voltage & Current Accuracy: ±0.02% F.S.
- Voltage & Current Precision: ±0.005% F.S.
- Minimum Discharge Voltage: 1.5V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Discharge Resistor
- Thermal Detector Included
- SMBUS Supported
CT-9008-5V15A-VT-SMB
- Voltage Range: ±5V
- Current Range: 15mA/150mA/1.5A/15A
- Voltage & Current Accuracy: ±0.02% F.S.
- Voltage & Current Precision: ±0.005% F.S.
- Minimum Discharge Voltage: 0.7V
- Recording Frequency: 100Hz
- Sampling Time: 10ms
- Current Response Time: ≤1ms
- Off-Line Test: 1GB
- Discharge Resistor
- Thermal Detector Included
- SMBUS Supported
Typical Applications
R&D Cell Validation
Used in battery R&D labs for cell development, prototype validation, and performance characterization across a wide range of test conditions.
Consumer Electronics Battery Testing
Designed for testing of consumer electronics batteries, enabling precise evaluation of cell performance under dynamic and high-current conditions.
Formation & Grading
Applicable to cell formation and capacity grading in small-batch and engineering-scale testing environments.
Academic Laboratories
Widely used in academic and research labs for electrochemical studies and experimental cell development.
Battery Recycling
Suitable for cell-level testing in battery recycling and second-life evaluation, supporting capacity assessment and performance screening of recovered cells.