NEWARE BATTERY RECYCLING SOLUTIONS:
COST-EFFECTIVE GRADING AND SORTING FOR REUSE

Neware battery testing solutions cover the entire battery recycling process: from safety assessment and pre-discharge of EV packs and modules, to precise battery grading and sorting of individual cells, and performance testing of refurbished packs. These systems provide accurate data on capacity, SOH, and safety, ensuring reliable second-life use and efficient recycling

EV Battery Recycling Flow — Pack → Module → Cell Intake Diagnostics · Safe Disassembly · Cell Grading & Routing PACK · Intake & Safety MODULE · Disassembly CELL · Testing & Grading PACK Intake & Safety SOH · Full Discharge · IR · Hazard Screening View this step MODULE Sorting Deactivation · DCIR · Balance · Lot Sorting View this step CELL Grading OCV · DCIR · Capacity · Reuse / Recycle View this step Step 1 · Intake & Safety Step 2 · Disassembly Step 3 · Cell Grading

Know Battery Sorting — And Why It Matters for Battery Recycling?

Battery sorting, often also referred to as battery grading, is the critical step in the battery recycling value chain. When end-of-life batteries are collected from electric vehicles (EVs), consumer electronics, and other applications, they are not all destined for immediate dismantling. Many still hold significant residual capacity and performance value — and this is where battery grading becomes essential.

Rather than defaulting to material recovery, battery grading identifies which batteries can be repurposed for second-life applications (such as energy storage systems or light-duty electric mobility) and which should be safely processed for resource recovery. This process improves overall recycling profitability, reduces carbon emissions, and conserves energy.

Key metrics such as remaining capacity, internal resistance, and self-discharge rate are tested using advanced battery diagnostic systems. Based on these results, batteries are efficiently sorted into: Reusable batteries for second-life use or Degraded batteries for recycling and raw material extraction

What Types of Batteries Are Suitable for Sorting

Not all end-of-life batteries are suitable for second-life applications, and their potential depends on recycling value, structural complexity, and market demand.

Power batteries (EV batteries) and medium-to-large lithium-ion systems, such as those used in telecom base stations, electric forklifts, and low-speed EVs, are ideal for battery grading and cascade utilization. EV batteries typically have high capacity and are organized in cells, modules, and packs, allowing stepwise disassembly, testing, and performance-based sorting at every level. Even after retirement, they retain significant residual energy, making them valuable for second-life applications.

In major markets like the U.S., Europe, and China, EV battery recycling is actively supported by policies and funding programs that promote advanced disassembly, pre-treatment, and reuse technologies.

By contrast, consumer electronics batteries, primary lithium cells, and alkaline batteries usually have low capacity or are already degraded at disposal, offering minimal value for grading or cascade utilization.

Cost-Effective Solutions

We understand that cost control is critical in battery recycling. By focusing on the essential equipment capabilities, improving system lifetime and durability, optimizing sorting process steps, and enhancing energy efficiency—combined with AI-based decision models—we can maintain accurate sorting results while maximizing production line throughput and minimizing sorting cost per cell.

Aged Pack Pre-treatment

Before disassembly, conducting full-pack evaluation and pre-discharge of retired battery packs is a critical pre-treatment step.

 Retired EV battery packs often retain high voltage and substantial residual energy. Without proper handling, direct dismantling risks electric shock, short circuits, thermal runaway, and even fire. A controlled pre-discharge process ensures safe energy release, while full-pack evaluation—capacity, internal resistance, remaining charge, and SOH—determines whether the battery is viable for second-life use or should move directly to material recycling.

The Neware 6 Series battery pack tester provides reliable solutions for full-pack evaluation and pre-discharge of retired EV battery packs. It combines precision, safety, and efficiency to support both battery grading and second-life applications.

✔ Pack Discharge: Discharge pack down to safe voltage level or fully depleted

✔ Pack Evaluation: Cycle testing for precise evaluation of pack performance

✔ BMS Diagnostics: Seamless integration for BMS data reading and fault analysis

✔ Energy Recovery: Discharge energy is fed back to the grid

✔ Flexible Simulations: Supports programmable charge/discharge steps

✔ Safety Logic: Programmable voltage, current, and temperature protection

Toyota Prius

✔ CE-6004n-400V150A-IG

Tesla

✔ CE-6002n-500V200A-IG

Nissan Leaf

✔ CE-6002n-500V200A-IG

Other Cars

Pack-platform Dependent
NEWARE Pack Tester Baseline Specifications
Parameter Data Notes
Voltage Accuracy 0.02% of FS Measurement accuracy for pack voltage.
Current Accuracy 0.02% of FS Measurement and output accuracy for charge/discharge current under rated range.
Power Factor ≥ 99% (Full Loads) At nominal power during regenerative operation to the grid.
THDi ≤ 5% (Full Loads) Total Harmonic Distortion of input current during regeneration.
System Efficiency (Max) 96% End-to-end discharge-to-grid efficiency at rated power.
Current Response Time ≤ 10ms Rise/settling time for step current commands.
Input Impedance ≥ 10MΩ High input impedance for precise voltage sensing.
Sampling Rate 100 Hz Data acquisition frequency for logging and control.
Notes: Some specifications vary by model; please refer to the model-specific datasheet.

Module Consistency Inspection and Sorting

Module Consistency Check

After pack disassembly, each module is connected to a Neware tester for OCV (open-circuit voltage) consistency measurement.

<30 mV → good consistency
>100 mV → requires further disassembly

Module Grading & SOH Evaluation

Modules with good consistency proceed to charge/discharge cycling to measure capacity and calculate SOH.

SOH >80% → second-life applications
SOH 50–80% → low-speed EVs or energy storage
SOH <50% → cell-level disassembly or recycling

Module doesn’t have BMS?

Use the built-in Aux Unit on the module tester to monitor each cell in real time with high accuracy—capturing detailed status and pinpointing faulty cells.

NiMH Module
(6S, 7.2V, 6.5Ah)

✔ CE-4008-10V10A-SR

Li-on Module
(74S6P, 25V, 233Ah)

✔ CE-6004n-60V300A-H

LMO Module
(2S2P, 7.6V, 60Ah)

✔ CE-6008n-30V100A-H

Other Module
(?)

module based solution

Cell Sorting & Grading

Batch of Cells Cylindrical cells input OCV / DCIR Gate 1: screening Capacity & SOH Gate 2: qualification Second-life Repurpose / reuse Discharge & Dismantle Fail route: safe discharge & teardown Pass Pass Pass Fail Fail

As the core unit of an EV battery pack, cells pose major challenges for grading due to their sheer volume and complex conditions. Safe, efficient, precise, and orderly cell grading requires a scientific process flow, appropriate sorting equipment, and a robust data management system.

The most common and recommended cell grading procedures include Physical check, OCV testing, DCIR testing, capacity testing, self-discharge testing, and thermal rise testing.

OCV (Open-Circuit Voltage)

OCV test is the first step in the cell grading process after screening out cells with physical defects such as damage or leakage. As one of the most basic, fastest, and non-destructive electrical performance tests, OCV measurement quickly identifies cells with abnormal voltage.

DCIR (Direct Current Internal Resistance)

DCIR (Direct Current Internal Resistance) is the ratio of voltage change to current change when a short current pulse is applied, reflecting a cell’s voltage response under DC conditions. Cells with high internal resistance show poor current output, generate excessive heat, and are unsuitable for high-rate loads. Only cells with low internal resistance are viable for continued use in power or energy storage applications.

Neware’s programmable battery grading system integrates OCV and DCIR testing in a single run. The system automatically performs DCIR testing only on cells that pass the OCV check, while cells with abnormal OCV are safely flagged and protected to prevent charge/discharge on damaged cells, thereby eliminating potential safety risks.

For example, in the simulated grading test shown on the right, Step 1 is a 30-second OCV check. If the system detects an OCV below 2.5 V, the cell is considered failed or internally damaged; above 4.2 V indicates overcharge and an abnormal state. Only cells within the normal voltage range and with a drift less than ±50 mV pass the initial OCV screening. If any Step 1 condition is triggered, the test for that cell stops immediately, and the cell is flagged as “damaged.” Only cells that pass Step 1 proceed to Steps 2–6, where DCIR is precisely evaluated through repeated short charge/discharge and rest cycles. Based on user-defined DCIR thresholds, the system automatically determines compliance and displays the results on the operation interface.

Example OCV&DCIR Test Step

Automatic Decision Logic 

Capacity & SOH Testing

After cells pass the rapid OCV and DCIR screening, they are reclassified. Cells with potential reuse value and safe charge/discharge behavior proceed to the capacity and SOH testing stage. Modules are loaded in trays into the Neware grading system, where cycling tests are performed to determine actual remaining capacity. The SOH is then calculated by comparing measured capacity against the rated capacity, and cells are classified accordingly.

In the illustrated example, cells first undergo 0.2C constant-current/constant-voltage charging (cut-off current: 0.05C) to ensure uniform SOC (fully charged). They are then discharged at 0.5C to 2.5V, repeating this cycle 3–5 times depending on grading throughput. The system automatically rates and categorizes cells based on SOH results, uploading all test data to the PLC or MES system.

Typical classification is as follows:

  • SOH > 80%: Suitable for power applications or high-demand energy storage

  • SOH 60–80%: Suitable for energy storage, low-speed EVs, or power tools

  • SOH < 60%: Recommended for material recycling

 

Why not start directly with capacity testing?

Because a single precise capacity measurement requires at least 2–3 full cycles, and at 0.2C–0.5C this means 8–30 hours of testing. Running all cells through direct cycling would not only tie up resources and fixtures, but also expose hidden high-risk cells to extended charge/discharge, creating additional safety hazards and reducing overall grading efficiency.

Self-Discharge Testing

Self-discharge testing is a key method to evaluate a battery’s internal stability and safety. By monitoring voltage drop or capacity fade during extended rest periods, it helps identify “latent defects” that may not appear in standard cycling tests.

For large-scale recycling projects (e.g., EV battery dismantling), self-discharge observation is recommended before capacity testing as a precautionary step. For module-level repurposing or energy storage integration, it is typically performed after capacity testing to validate long-term stability.

Two methods are commonly used:

  1. OCV Drop Method: For example, an 18650 lithium-ion cell is charged at 0.2–0.5C to 4.2 V with a cut-off current of 0.05C, rested for 1–7 days, and the initial and subsequent OCV values recorded. Self-discharge rate (%/month) is calculated as:
    (Vinitial − Vfinal) / Vinitial × (30 / days tested) × 100%

  2. Capacity Loss Method: After full charge and N days of rest, discharge at 0.2C or 0.5C to measure capacity, then compare with pre-rest capacity to determine capacity loss.

Typical thresholds:

  • Healthy NMC or LFP cells: <3%/month

  • Normal used cells: 3–5%/month

  • High-risk cells: >5–10%/month, or voltage drop >30 mV/day 

Temperature Rise Testing

Temperature rise testing measures changes in a cell’s surface or internal temperature during rest, charge, and discharge, providing critical evaluation of thermal stability, safety, and abnormal internal reactions.

This test can be seamlessly integrated with capacity or self-discharge testing. For example, during a charge/discharge cycle (e.g., 0.2C CC-CV charge to full followed by 0.2C discharge), real-time monitoring of cell temperature directly yields temperature rise data.

Common abnormal temperature rise phenomena include:

  • Temperature increase >10 °C during discharge

  • Continuous temperature rise during rest

  • Severe temperature fluctuations (>3 °C variation)

Select Your Most Suitable Cell Grading Solution

BTS-4000 Battery Tester

Manual Operation

Semi-Auto Grading System

Full Automation except Loading

Automatic Grading Line

Robotic Loading with Full Automation

Get Expert Solutions and Quotes

Submit your request and we will respond within 2 business hours.