NEWARE ENERGY STORAGE SYSTEM TESTING SOLUTIONS

Neware provides advanced BESS testing solutions for vertically integrated manufacturers and energy storage system integrators, combining system-level validation with industry-leading performance testing to comprehensively evaluate system performance, safety, and lifecycle reliability—from Battery Pack and Battery Cluster to Battery Container across the full testing scope.

ESS Architecture & Testing Scope

The battery is the core of an Energy Storage System (ESS), responsible for storing and delivering electrical energy. Its performance directly impacts the system’s capacity, efficiency, and service life.

The Battery Management System (BMS) safeguards battery operation by monitoring voltage, current, and temperature, while performing cell balancing and protection against abnormal conditions.

Neware’s testing solutions focus on the battery and BMS layers, enabling comprehensive validation of performance, safety, and reliability for energy storage systems.

Where BESS Testing Meets Real Challenges

Energy Cost

In energy storage system testing, daily power consumption often reaches the megawatt level.

With conventional testing equipment, the energy generated during discharge cannot be recovered and is instead dissipated as heat, resulting in significant energy waste.

In long-term cycling test scenarios, the accumulated energy consumption continues to increase, making energy cost a major operational burden in energy storage testing.

Neware 6000 Series adopts a bidirectional DC/DC converter architecture. 

During discharge, the energy from the channels is fed back to the DC bus and reused by channels in charging mode, rather than being dissipated as heat through resistors as in traditional systems. 

This design effectively reduces energy waste and significantly improves overall system efficiency.

Energy flow path: Discharging channel → DC Bus → Charging channel

Transformer Capacity Limitation

In container-level energy storage system testing, the required testing power often reaches the megawatt level.

However, the transformer capacity at many testing sites was originally designed for cell or battery pack testing, resulting in limited power supply capability.

When conducting high-power system-level tests, the required power often exceeds the available grid connection capacity.

As a result, laboratories may struggle to perform full-power testing or operate multiple test systems simultaneously, significantly limiting the scalability and efficiency of energy storage testing.

Neware 6000 Series adopts a regenerative architecture.

Through a bidirectional AC/DC converter, the energy generated during discharge can be fed back to the grid and reused by other charging channels.

This enables simultaneous testing of multiple energy storage containers while significantly reducing grid power demand, as the grid only compensates for system losses.

Energy flow path: Battery Container (Discharging)→ AC/DC Converter →Grid →AC/DC Converter → Battery Container (Charging)

Cabinet Power Limitation

Battery containers typically consist of multiple battery clusters connected in parallel, with testing power often reaching the megawatt level.

However, due to limitations in the physical size and thermal dissipation capabilities of power electronic components, the output power of a single test cabinet is inherently limited.

Under these constraints, adding more test channels in parallel within a single cabinet cannot increase the maximum output power of the system, making it difficult to meet the testing requirements of megawatt-level energy storage systems.

Neware 6000 Series features a scalable architecture enabled by customized software and hardware design.

 The system supports multi-cabinet parallel configuration, allowing flexible expansion of testing power and channel capacity according to testing requirements. 

This enables megawatt-level testing for energy storage systems and supports testing across multiple levels, including Battery Pack, Battery Cluster, and Battery Container.

Safety Risks

BESS testing typically involves high-voltage, high-current, and high-power operating conditions.

The massive energy flow not only imposes significant electrical and thermal stress on power components inside the cabinet, but also introduces potential risks to personnel safety and grid stability.

Ensuring safe, stable, and reliable testing under such high-power conditions has therefore become a critical challenge that BESS testing systems must address.

This requires comprehensive protection mechanisms and robust system-level safety design to ensure reliable operation during high-power testing.

Neware 6000 Series integrates multi-layer protection through both software and hardware mechanisms. 

Software protection enables flexible configuration of safety parameters such as voltage and current limits with protection delays for real-time monitoring and rapid response. 

Hardware protection includes reverse polarity, overvoltage, overcurrent, overtemperature, and emergency stop protection, ensuring safe and reliable operation under high-power testing conditions.

Why Neware for Battery Energy Storage System Testing

The system supports parallel operation of multiple cabinets, with each test cabinet providing 600 kW of power output.

By flexibly configuring multiple cabinets, a megawatt-level testing system can be built to meet the testing requirements of large-scale energy storage systems.

Learn more about CE 6000 >

The system adopts a modular architecture with independently designed AC/DC and DC/DC power modules, which not only improves overall system stability but also enables module-level rapid maintenance.

 In the event of a failure, the system can be quickly restored to operation simply by replacing the corresponding module.

Learn more about CE 6000 >

By adopting high-frequency isolation technology, the system eliminates bulky line-frequency transformers, significantly reducing the overall size and weight of the equipment.

For example, a 600 kW cabinet occupies only about 0.9 m² of floor space and weighs approximately 700 kg.

Learn more about CE 6000 >

The system supports multiple communication protocols, including Ethernet, CAN FD, CAN, and RS485, enabling seamless data interaction with BMS systems.

It also supports DBC configuration, allowing users to import and export DBC files and customize CAN message settings. In addition, the system can achieve integrated control with external equipment such as chillers, temperature chambers, and vibration test systems.

Learn more about CE 6000>

From Cell to ESS: Battery Testing for Vertically Integrated Manufacturers

VOLTAGE RANGE

5 V to 3000 V.
Ready for every scale.

5 V 60 V 200 V 1000 V 1500 V 3000 V
Low voltage 5 / 6 V Cell testing
Medium voltage 30–200 V 30 · 60 · 120 · 200 V
High voltage 300–1000 V 300 · 400 · 500 · 800 · 1000 V
Ultra-high voltage 1500–3000 V 1500 · 3000 V

Cell Cycler

  • Capacity: 280 Ah
  • Chemistry: LFP(LiFePO₄)
  • Nominal Voltage: ~3.2 V
  • Energy: ~896 Wh
  • Form factor: Prismatic
CE-6016n-6V300A
  • Voltage: 5V/6V
  • Current: 50A/9600A
  • Voltage & Current Accuracy: ±0.05% F.S.
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • Regenerative Design

  • Parallel Mode: Supported

Learn more about Neware Cell Cycler >

Pack Cycler

  • Capacity: 280 Ah
  • Chemistry: LFP (LiFePO₄)
  • Nominal Voltage: ~166.4 V
  • Energy: ~46.6 kWh
  • Configuration: 52S1P
  • Voltage Range: 20V-200V
  • Current Range: 20A-1200A
  • Voltage & Current Accuracy: ±0.05% F.S.
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Parallel Mode: Supported

Learn more about Neware Pack Cycler >

ESS Cycler

  • Energy: ~5 MWh
  • Battery Chemistry: LFP (LiFePO₄)
  • Nominal Voltage: ~1200–1500 V DC
  • Cell Type: 280Ah / 314Ah Prismatic
  • Configuration: Multi-rack Battery System
  • Voltage Range: Up to 3000V
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤10ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Parallel Mode: Supported

Learn more about Neware ESS Cycler >

Energy Storage System Testing for All Applications

C&I

Commercial & Industrial

Typical applications include:

  • Commercial battery energy storage systems
  • Industrial energy storage installations
  • Data center backup power systems

Key focus:

  • High-power battery testing
  • System performance validation
  • Long-duration cycling and reliability testing

Utility

Utility-Scale Storage

Typical applications include:

  • Grid-scale battery energy storage systems (BESS)
  • Renewable energy integration (solar / wind + storage)
  • Public infrastructure energy storage

Key focus:

  • Large-capacity battery testing
  • High-power DC performance testing
  • System-level validation and safety testing

Home

Residential Storage​

Typical applications include:

  • Home battery storage systems
  • Solar + Storage (PV + ESS) solutions
  • Residential backup power systems

Key focus:

  • Battery pack performance testing
  • BMS management system validation
  • Charge/discharge cycle testing

Talk to a sales engineer>

BMS Protection Validation According to IEC 63056

Neware BESS Test Setup

Battery Cycler

CAN Communication Box

Battery System with BMS

Test Procedure Using Neware BTS Software

BMS Over-discharge Protection Test

  1. Step 01

    Initial State Conditioning

    Allow the battery to rest, then discharge it to the cut-off voltage specified by the manufacturer.

  2. Step 02

    Manufacturer-Specified Full Charge

    Fully charge the battery using the charging method specified by the manufacturer.

  3. Step 03

    Adjust to the Specified Test SOC

    Discharge the battery to the target SOC.

  4. Step 04

    Verify BMS Over-discharge Protection

    Continue discharging until the BMS activates over-discharge protection and disconnects the discharge circuit.

  5. Step 05

    Post-test Observation

    Allow the battery to rest, then record and inspect its post-test condition.

From Materials Research to Scalable Validation

Neware’s testing systems span the entire workflow from battery materials research and cell validation to scale-up testing, minimizing the risk of data discontinuity across R&D stages, reducing redundant validation, and accelerating research efficiency and product iteration.

Flexible Expansion for Multi-Parameter Testing

Neware’s testing systems allow flexible integration of auxiliary channels for voltage, temperature, and pressure monitoring, supporting multi-parameter testing and smooth system expansion throughout different stages of battery research and validation.

Powerful and User-Friendly Data Analysis Software

Neware’s software features an intuitive interface and flexible data analysis tools, enabling users to define custom curves, configure axes freely, and export test data in common formats such as Excel, TXT, and CSV for efficient post-processing and collaboration.

High-Precision Measurement for Reproducible Results

Neware’s testing systems leverage industry-leading resolution, precision, and accuracy to deliver stable and highly reproducible data. Over the past 27 years, our systems have been adopted by over 90% of the world’s leading universities and research institutions.