NEWARE EV Cell Testing:
OCV, DCIR, Capacity, Cycles, Smart Screening
Reliable, Precise, and Versatile
OCV & DCIR
OCV
As one of the most basic, fastest, and non-destructive electrical performance tests, OCV measurement quickly identifies cells with abnormal voltage.
In EV cell testing, Neware battery testers enable millisecond-level OCV acquisition with ultra-high accuracy of 0.02% FS, providing stable and repeatable voltage data for large-scale cell screening, grading, and consistency evaluation
DCIR
Integrated OCV–DCIR Test Logic with Built-in Safety Protection
Neware’s programmable battery testing system integrates OCV and DCIR tests in a single run. The system automatically performs DCIR testing only on cells that pass the OCV check, while cells with abnormal OCV are safely flagged and protected to prevent charge/discharge on damaged cells, thereby eliminating potential safety risks.
For example, in the simulated grading test shown on the right, Step 1 is a 30-second OCV check. If the system detects an OCV below 2.5 V, the cell is considered failed or internally damaged; above 4.2 V indicates overcharge and an abnormal state. Only cells within the normal voltage range and with a drift less than ±50 mV pass the initial OCV screening. If any Step 1 condition is triggered, the test for that cell stops immediately, and the cell is flagged as “damaged.” Only cells that pass Step 1 proceed to Steps 2–6, where DCIR is precisely evaluated through repeated short charge/discharge and rest cycles. Based on user-defined DCIR thresholds, the system automatically determines compliance and displays the results on the operation interface.
Example OCV&DCIR Test Step
Automatic Decision Logic
Capacity and Cycles
The left side shows a practical example of the Neware programmable system. The battery is first charged at a constant current and constant voltage of 0.2 C (cut-off current 0.05 C), then discharged at 0.5 C down to 2.5 V, for a total of three cycles.
How Key Parameters Affect Battery Tester Accuracy?
- Voltage & Current Accuracy:
Determine how closely the tester’s measurements and outputs match the true electrical values. Higher accuracy ensures reliable and repeatable charge/discharge results. - Multi-Range Design:
Automatically adjusts the measurement range to maintain high resolution across large current or voltage spans, ensuring precision at both high and low signal levels. - High Sampling Frequency:
Reduces the sampling interval (ΔT), allowing the tester to capture finer changes in current and voltage. A smaller ΔT improves the integration accuracy when calculating capacity and energy, especially during dynamic cycles. High Input Impedance:
Minimizes current draw from the cell during voltage measurement, preventing signal disturbance and ensuring precise OCV or leakage tests.
| Parameter | Data | Notes |
|---|---|---|
| Voltage Accuracy | 0.02% of FS | Measurement accuracy for pack voltage. |
| Current Accuracy | 0.02% of FS | Measurement and output accuracy for charge/discharge current under rated range. |
| Current Response Time | ≤ 10ms | Rise/settling time for step current commands. |
| Input Impedance | ≥ 10MΩ | High input impedance (low leakage) for precise voltage sensing. |
| Sampling Rate | 100 Hz | Data acquisition frequency for logging and control |
Typical EV Cells Practical Example