NEWARE EV Cell Testing:
OCV, DCIR, Capacity, Cycles, Smart Screening

Reliable, Precise, and Versatile

EV Pack Diagnostics Flow — PACK → MODULE → CELL Find the fault fast: localize at pack, isolate at module, verify at cell PACK / System-Level Checks MODULE / Isolation & Triage CELL / Testing & Evaluation PACK Diagnostics & Fault Localization OCV/SOC/SOH · DCIR/HPPC · Insulation/HVIL CAN DTC → Flag suspect module(s) Visit this page MODULE Isolation & Triage ΔV/ΔIR scan · Balance state · Thermal check CAN (BMU) → Pinpoint bad cell group Visit this page You are here CELL Testing & Evaluation OCV/SOC · DCIR · Capacity/Efficiency Self-discharge → Root cause / Grading

OCV & DCIR

OCV

As one of the most basic, fastest, and non-destructive electrical performance tests, OCV measurement quickly identifies cells with abnormal voltage.
In EV cell testing, Neware battery testers enable millisecond-level OCV acquisition with ultra-high accuracy of 0.02% FS, providing stable and repeatable voltage data for large-scale cell screening, grading, and consistency evaluation

DCIR

DCIR measurement evaluates the internal resistance characteristics of EV cells under controlled current excitation, providing a direct indicator of cell health, power capability, and consistency. Using Neware battery testers, DCIR can be measured with high precision and repeatability, enabling accurate cell-to-cell comparison and early detection of degradation, imbalance, or manufacturing variation.

Integrated OCV–DCIR Test Logic with Built-in Safety Protection

Neware’s programmable battery testing system integrates OCV and DCIR tests in a single run. The system automatically performs DCIR testing only on cells that pass the OCV check, while cells with abnormal OCV are safely flagged and protected to prevent charge/discharge on damaged cells, thereby eliminating potential safety risks.

For example, in the simulated grading test shown on the right, Step 1 is a 30-second OCV check. If the system detects an OCV below 2.5 V, the cell is considered failed or internally damaged; above 4.2 V indicates overcharge and an abnormal state. Only cells within the normal voltage range and with a drift less than ±50 mV pass the initial OCV screening. If any Step 1 condition is triggered, the test for that cell stops immediately, and the cell is flagged as “damaged.” Only cells that pass Step 1 proceed to Steps 2–6, where DCIR is precisely evaluated through repeated short charge/discharge and rest cycles. Based on user-defined DCIR thresholds, the system automatically determines compliance and displays the results on the operation interface.

Example OCV&DCIR Test Step

Automatic Decision Logic 

Capacity and Cycles

The left side shows a practical example of the Neware programmable system. The battery is first charged at a constant current and constant voltage of 0.2 C (cut-off current 0.05 C), then discharged at 0.5 C down to 2.5 V, for a total of three cycles.

How Key Parameters Affect Battery Tester Accuracy?

  • Voltage & Current Accuracy:
    Determine how closely the tester’s measurements and outputs match the true electrical values. Higher accuracy ensures reliable and repeatable charge/discharge results.
  • Multi-Range Design:
    Automatically adjusts the measurement range to maintain high resolution across large current or voltage spans, ensuring precision at both high and low signal levels.
  • High Sampling Frequency:
    Reduces the sampling interval (ΔT), allowing the tester to capture finer changes in current and voltage. A smaller ΔT improves the integration accuracy when calculating capacity and energy, especially during dynamic cycles.
  • High Input Impedance:
    Minimizes current draw from the cell during voltage measurement, preventing signal disturbance and ensuring precise OCV or leakage tests.

NEWARE Cell Tester Baseline Specifications
Parameter Data Notes
Voltage Accuracy 0.02% of FS Measurement accuracy for pack voltage.
Current Accuracy 0.02% of FS Measurement and output accuracy for charge/discharge current under rated range.
Current Response Time ≤ 10ms Rise/settling time for step current commands.
Input Impedance ≥ 10MΩ High input impedance (low leakage) for precise voltage sensing.
Sampling Rate 100 Hz Data acquisition frequency for logging and control
Notes: Some specifications vary by model; please refer to the model-specific datasheet.