NEWARE EV Module Diagnostics & Testing:
High Performance, Cell Status, CAN, Operating Envelope
NEWARE’s EV Module Tester delivers lab-grade diagnostics for battery modules: capacity, SOC/SOH, DCIR/HPPC power, CAN BMS data, and Operating Envelope checks. Kelvin 4-wire, ±0.02% FS V / ±0.05% FS , 100 Hz logging, and ~10 ms response capture fast transients. Regenerative discharge (~90% eff.) and auto reports enable safe, repeatable, standards-aligned testing.
High Performance: 0.05% FS & 100Hz
NEWARE Battery Module Tester is a high-precision, bidirectional charge/discharge system purpose-built for high-power EV battery modules. It delivers fast dynamic response, stable accuracy, and flexible multi-channel configurations for core use cases: pulse testing, cycle-life testing, and drive-profile (duty-cycle) simulation.
With regenerative energy recovery and multi-channel inputs, it cuts test energy consumption and thermal load. The platform uses a bidirectional high-frequency DC conversion topology and multi-channel 24-bit ADCs to achieve 0.05% FS current accuracy, 100 Hz data-sampling rate, and ≈10 ms current response time—providing higher resolution and tighter control than conventional single-range instruments. This makes it ideal for EV module diagnostics, characterization, and validation.
| Parameter | Data | Notes |
|---|---|---|
| Voltage Accuracy | 0.02% of FS | Measurement accuracy for pack voltage. |
| Current Accuracy | 0.05% of FS | Measurement and output accuracy for charge/discharge current under rated range. |
| Power Factor | ≥ 99% (Full Loads) | At nominal power during regenerative operation to the grid. |
| THDi | ≤ 5% (Full Loads) | Total Harmonic Distortion of input current during regeneration (per IEC/GB limits). |
| System Efficiency (Max) | 90% | End-to-end discharge-to-grid efficiency at rated power. |
| Current Response Time | ≤ 10ms | Rise/settling time for step current commands. |
| Input Impedance | ≥ 10MΩ | High input impedance (low leakage) for precise voltage sensing. |
| Sampling Rate | 100 Hz | Data acquisition frequency for logging and control |
Typical Module Solution Example
Module Diagnostics (Capacity, SOC, SOH, DCIR)
- Capacity — lab grade accuracy
- Precision measurement chain + high input impedance (low leakage) for exact coulomb counting
- Fully programmable charge/discharge profiles to simulate real duty cycles
- Repeatable cycle-life capacity tests with consistent results
- SOC — automatic & aligned
- Auto-calculated during the run (coulomb counting + OCV alignment)
- SOH — capacity & impedance in one view
- Auto computation from measured capacity and resistance trends
- Clear pass/fail and historical comparison in the same report
- DCIR — fast, clean pulse measurements
- 100 Hz sampling captures transients reliably
- <10 ms current response for crisp ΔV/ΔI results
Module-Level Cell Consistency
Module doesn’t have BMS?
Use the built-in Aux Unit on the module tester to monitor each cell in real time with high accuracy—capturing detailed status and pinpointing faulty cells.
Pack Diagnostics — Clean Main Channel & CAN Routing
Operating Envelope Simulation
Neware’s new Operating Window enables full-pack operating envelope validation and simulation without the vehicle BMS. Define limits across SOC and temperature, apply dynamic lookups, and reproduce real-world charge/discharge limits to measure an EV battery pack’s true performance under varying conditions—ideal for rapid calibration, strategy verification, and limit testing.
Up to 3-D Matrix can be loaded into the system to produce dynamic values, and the tester updates output current/power in real time based on the lookup results.
Discharge Energy Regenerative
NEWARE module testers feature regenerative discharge (up to 90% efficiency), returning discharged energy back to the grid to minimize waste. By avoiding resistive heat dumping, regeneration cuts thermal load, which reduces lab HVAC burden, prevents hot spots and thermal drift, lowers fan noise and wear, and mitigates temperature-induced derating or safety risks during long tests. The result is cleaner energy usage, steadier test conditions, and longer equipment life.
Get Expert Solutions and Quotes