Module & Pack Cycler

  • Real-Time SMBus/I²C Communication
  • Advanced Test Logic for Smart Battery Validation
  • One Testing Platform for 99% SMBus/I2C Battery Applications
  • High-Precision Measurement and Sampling

Designed for smart battery testing with native SMBus/I²C communication.
Supports real-time BMS data monitoring, command read/write, and protocol-level interaction for portable and intelligent battery systems.

  • Real-Time BMS Communication During Battery Testing
  • Validate Battery Performance Under Real Driving Conditions
  • High-Efficiency Energy Regeneration
  • Flexible Parallel Architecture

Designed for EV and BESS with CAN/CAN FD communication.
Enables real-time interaction with automotive BMS protocols during charge and discharge testing.

BTS-6000 Module & Pack Cycler

Key Features

CAN & RS485 Communication with BMS

Supports CAN bus and RS485 communication with different types of battery packs, enabling reliable data exchange with BMS and external systems. 

By importing DBC files into NEWARE BTS 8.0.0 software, charge and discharge data as well as BMS status information are seamlessly integrated into the BTS interface, allowing intuitive test control and real-time battery status monitoring.

Driving Cycle Simulation

Supports driving cycle simulation testing for battery packs. By loading driving cycle files in Excel or TXT format, the system accurately reproduces real-world operating conditions to verify battery pack performance under actual application scenarios.

The system supports loading up to 1 million rows of driving cycle variation data, meeting the requirements of complex operating conditions and long-duration testing scenarios.

Multi-Level Parallel Design

Supports multi-channel parallel operation to significantly increase test current capability, meeting high C-rate charge and discharge testing requirements and comprehensively expanding system testing capability.

Supports multi-cabinet parallel operation to achieve megawatt-scale high-power output, suitable for high-power testing of large-scale energy storage systems and containerized energy storage applications.

Optimized Isolation Design

High-frequency isolation is adopted in the module cycler to achieve a compact design, fast dynamic response, and high power density, enabling flexible and efficient module testing.

Power-frequency isolation is adopted in the pack cycler to provide enhanced electrical safety, reliability, and long-term operational stability for high-voltage battery pack testing. 

Most Popular Models

CE-6016n-30V30A-H

  • Voltage Range: 0V-30V
  • Current Range: 30A
  • Voltage Accuracy: ±0.1% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Minimum Discharge Voltage: 3V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 120A

CE-6016-60V30A-H

  • Voltage Range:0V-60V
  • Current Range: 30A
  • Voltage Accuracy: ±0.05% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Minimum Discharge Voltage: 3V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 120A

CE-6002n-200V200A-H

  • Voltage Range: 0V-200V
  • Current Range: 25A/50A/100A/200A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Minimum Discharge Voltage: 5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 400A

CE-6002n-750V300A-IG

  • Voltage Range: 0V-750V
  • Current Range: 300A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Minimum Discharge Voltage: 10V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤5ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 600A

CE-6004n-1520V400A

  • Voltage Range: 0V-1520V
  • Current Range: 400A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.02% F.S.
  • Minimum Discharge Voltage: 100V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤10ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 1600A

CE-6004n-3000V200A

  • Voltage Range: 0V-3000V
  • Current Range: 200A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.05% F.S.
  • Minimum Discharge Voltage: 100V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤1ms
  • Off-Line Test: 1GB
  • DBC Configuration
  • Regenerative Design
  • Maximum Current in Parallel Mode: 800A

Not sure which product is the best fit? Contact expert for professional solution

BTS-5000 Module & Pack Cycler

Key Features

SMBUS/I2C communication

Supports SMBus/I²C communication for battery packs used in laptops, tablets, smartphones, power tools, and small drones, enabling reliable data interaction and efficient testing.

By importing DBC files into NEWARE BTS 9.0.0 software, charge and discharge data together with real-time battery status information are seamlessly integrated into the BTS interface, enabling intuitive test control and comprehensive monitoring.

Regenerative Design

CE-5000 models integrate advanced inverter and energy regeneration technology to reduce energy loss during testing. Compared with traditional resistive discharge systems, no complex water-cooling is required, and heat-related fan noise is minimized for quieter and simpler operation.

During charge and discharge testing, discharged energy is recovered and fed back for reuse, improving overall efficiency while significantly lowering energy consumption and long-term operating costs.

High Precision and Sampling Rate

The system supports high-precision voltage and current measurement with accuracy up to ±0.02% F.S., combined with a 100 Hz sampling rate to ensure data accuracy and stability.

This level of precision and sampling capability provides reliable technical assurance for data and curve consistency as well as reproducibility during long-term cycling and batch testing, establishing a stable foundation for data analysis and performance evaluation.

Advanced Logic & Flexible Data Recording

Users can create custom variables and mathematical expressions to build complex control logic. Built-in parameters, imported DBC variables, and user-defined variables can all participate in step calculations and conditional execution, providing powerful flexibility for advanced and customized testing requirements.

In addition, the system supports on-demand variable recording. Users can choose which variables are saved in the test data and which are used only for display or calculation, making data clearer and management more efficient.

Most Popular Models

CT-5008-5V6A-SMB-TX

  • Voltage Range: 0.5V-5V
  • Current Range: 0.2A/1A/6A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.02% F.S.
  • Minimum Discharge Voltage: 0.5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤2ms
  • Off-Line Test: 1GB
  • Built-in voltage and temperature measurement capability
  • Supports SMBus / I²C communication

CT-5008-5V12A-SMB-TX

  • Voltage Range: -2.5V-5.0V
  • Current Range: 1A/4A/12A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.02% F.S.
  • Minimum Discharge Voltage: -2.5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤2ms
  • Off-Line Test: 1GB
  • Built-in voltage and temperature measurement capability
  • Supports SMBus / I²C communication

CE-5008-10V20A-SMB

  • Voltage Range:2.5V-60V
  • Current Range: 20A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.02% F.S.
  • Minimum Discharge Voltage: 2.5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤3ms
  • Off-Line Test: 1GB
  • Regenerative Design
  • Supports SMBus / I²C communication

CE-5008-24V15A-SMB

  • Voltage Range: 2.5V-24V
  • Current Range: 15A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.03% F.S.
  • Minimum Discharge Voltage: 2.5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤20ms
  • Off-Line Test: 1GB
  • Regenerative Design
  • Supports SMBus / I²C communication

CE-5008-20V20A-SMB

  • Voltage Range: 2.5V-30V
  • Current Range: 20A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.03% F.S.
  • Minimum Discharge Voltage: 2.5V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤30ms
  • Off-Line Test: 1GB
  • Regenerative Design
  • Supports SMBus / I²C communication

CE-5008-30V10A-SMB

  • Voltage Range: 3V-30V
  • Current Range: 20A
  • Voltage Accuracy: ±0.02% F.S.
  • Current Accuracy: ±0.02% F.S.
  • Minimum Discharge Voltage: 3V
  • Recording Frequency: 100Hz
  • Sampling Time: 10ms
  • Current Response Time: ≤20ms
  • Off-Line Test: 1GB
  • Regenerative Design
  • Supports SMBus / I²C communication

Typical Applications

Battery Material Research

Used for evaluating lithium-ion and sodium-ion battery materials under precise low-current test conditions.

Coin Cell Testing

Designed for CR2032, CR2025, and other coin cells, supporting formation and low-rate cycling tests.

Low-Power & IoT Device

Suitable for testing small-capacity batteries in IoT and low-power electronic devices under mA-level currents.

Academic Laboratories

Widely used in academic and research laboratories for electrochemical studies and experimental cell development.