This is a question from one of our BTS4000 customers.
We found it very useful in our development to run a pulse charging regime. For example we loop 54 seconds of CCCV followed by 6 seconds of Rest. (The CCCV contains the exit condition)
The functionality of the BTS4000 allows to do it.
However- It collects too many records (two records each time the run moves from one step to the other…). This is too many for file size of many days cycle life. (and for excel)
My questions: Is there a way to-
1. disable the auto-record taking at each step transition. (most important ! )
2. to refer in a step exit condition to a channel (multi step) process value as accumulative charge, or discharge.
3. to refer in step exit condition to a channel virtual parameter as counter, formula.. and so.
In fact, for the above questions, we can use the ‘professional step editor‘ in the BTS client software to solve them.