Get to Know BTS9000

BTS9000 is based on Neware 6th-generation testing system. It’s designed for battery material research, high-precision tests, pulse charge/discharge tests, DCIR test, and cycle life test.

As the most cutting-edge equipment for battery material research, BTS9000 comes with extremely high accuracy(±0.02% of FS), amazing hardware response speed(≤100μs), wide range of applications, high-speed testing data acquisition and many other industry-proven characteristics, it’s your ultimate choice for battery material research!

Comes to the pulse tests, BTS9000 supports GSM(Global System for Mobile Communications), GPRS(General Packet Radio Service), CDMA-standby, CDMA-talk(Code Division Multiple Access), IDEN(Integrated Digital Enhanced Networks), etc. It characterized with a data acquisition frequency up to 1000Hz, an accuracy of 0.02% FS and a minimum pulse width of 400us (microsecond) which can be utilized for GSM or some other rapid pulse tests.

FEATURES AND FUNCTIONS

◆Extremely high accuracy(±0.02% of FS)

◆Hardware Response Time: ≤100μs

◆Min pulse width: 400μs

◆Adaptable to a wide range of products (cells, batteries, super-capacitors and battery modules, etc.)

◆Wide range of applications (grading, over charging/discharging, ladder-type charge/discharge, pulse)

◆DCIR, HPPC and GSM Pulse tests supported

◆4 channels paralleled available

◆Multi-current range available(4 ranges per channel)

◆Every channel can be user programmed to operate in steps of CCC(Constant Current Charging), CVC(Constant Voltage Charging), CC&CVC(Constant Current & Constant Voltage Charging), CPC(Constant Power Charging), CCD(Constant Current Discharging), CPD(Constant Power Discharging), Pulse, DCIR, etc.

◆Completely independent channels allow users to run multiple independent tests simultaneously without affecting other channels

◆With the BTS client software, data is easily viewed graphically

◆Diverse alligators and probe connection accessories for choose

HARDWARE SPECIFICATIONS

◆Input Power: AC 220V ±10% 50Hz

◆Voltage Output Range: 0 – 5V

◆Resolution: AD(16bit); DA(16bit)

◆Control Accuracy: ±0.02% of FS

◆Measuring Accuracy: ±0.02% of FS

◆Hardware Response Time: ≤100μs (10%-90% Current)

◆Data recording rate: up to 1000Hz, △T/△U/△I

◆Operating modes: Charge – CC(Constant Current),CV(Constant Voltage), CC&CV(Constant Current & Constant Voltage), CP(Constant Power), Pulse

◆Discharge- CC(Constant Current), CV(Constant Voltage), CR(Constant Resistance), CP(Constant Power), Pulse

◆Min pulse width: 400μs

◆Multi range: Each channel supports 4 ranges

Panels illustration

◆Front Panel

◆Rear Panel

Comments are closed.