On BTSDA, the formula to calculate charge/discharge DCIR is R= |(V1-V2)| / |(I1-I2)| Charge DCIR: Using first second record V1 and I1 at current charge step, minus the last second record V2 and I2 at previous charge step. Take the absolute value for (V1-V2) and (I1-I2), we can get DCIR via absolute current value divide by absolute voltage value. Discharge DCIR:Using
Can view detailed data information; Customize the displayed data: Click on “Cycle Layer Data” / “Work Step Layer Data” / “Record Layer Data”, right click on the header to add or cancel the displayed data type. If you have any other questions, please contact me with nucky@newarebattery.com
Can view the basic information of the test, such as start, finish, interrupt and other information. If you have any other questions, please contact me with nucky@newarebattery.com
Principle behind the setting: The battery material is divided into 2 groups called anode and cathode. Anode or positive electrode will be charged first and discharged later. Charge and discharge rate is discharge capacity/charge capacity. Cathode or negative electrode will be discharged first and charged later. Charge and discharge rate is charge capacity/discharge capacity. The default display setting for cycle
To do DCIR test, DCIR = △V/△I =(V2-V1)/(I2-I1) The following steps will guide you how to generate your DCIR report. “DCIR step, customize V1,I1,V2,I2, generate report” If you have more questions, please contact me with: collin@newarebattery.com
Click zoom in tool on the left corner of toolbar, select the area you want to zoom in. There is another method to zoom in/out the graph, click flex tool which is next to the zoom in tool. Select the area you want to zoom in/out, scroll up for zoom in and scroll down for zoom out. Or you can hold
Users can set up parameter based on their own requirements, including setting unit, setting log light, cycle layer, step layer, record layer, setting background color. To set up the parameter, simply right click. Setting unit Setting log light Cycle layer Step layer Record layer Setting background color If you have more questions, please contact me with: collin@newarebattery.com
User can copy all the data from software based on their requirements. If you have more questions, please contact me with: collin@newarebattery.com
Driving Cycle Simulation BTS8000 Testing System is an upgraded version which is focusing on EV Battery Test, Electrical Tool Battery Test, Super Capacitor Test and Engine Starting Battery Test. Driving Schedules Simulating is one of the most important competitive advantage which needs to be dressed out, it can provide a mock environment of the actual vehicle’s driving schedules and how would it perform
Can Neware build a script that can accumulate capacity between steps? Meaning instead of resetting capacity at end of every step, is there an option to do so? This is a question from our customer.We can tell from the below screenshot, customer wanted the raw capacity and energy data to accumulate during charge, discharge regardless the number of steps. Please