Tag: Neware software

8
Mar

Testing channel completed/paused status

There are 3 status (stopped,finished,protected) indicate that testing channels are completed or paused. You can view the previous testing status, every time you connect the tester to the server. Finished: Working step have been completed. Stopped: Working step haven’t completed, testing channel is paused. Protected: It have reached some of protection conditions(Eg Voltage limitation…), channel is paused to protect the

Read more

2
Mar

History Data

Select Server IP and middle machine model first, and then click the “History Data”. 2. On the “History Data” interface, select “Research”, and then we can see all information of this middle machine of this Server. 3. All history data of this middle machine will be ordered based on the starting time, select the serial number, the interface on the

Read more

2
Mar

Single Start

Select the channel to be operated, right-click and select “Single Start”. On the “start” interface, we can set the working step, record condition, and protect condition. Click OK, the channel will start working. *Note: The “start” interface contains “Standard Settings” and “Professional Settings”. “Standard Settings” : set the working step as a whole. “Professional Settings” : every single working step

Read more

2
Mar

Single Stop

If we want to reset, stop or pause the working steps of one or more chanles, we need to “Single Stop”. Right-click and select “Single Stop” on the channel that you want to set. As you can see, the working channel has been stopped.

2
Mar

Unit Setting

Neware BTS software provides users a very simple and flexible way to set their needed units according to different testing requirements . Right-click the interface on the software, and select “Unit Setting”. We can set: Volt. (V/mA), Cur. (A/mA/μA), Cap. (Ah/mAh), Temp. (°C/°F), R. (Ω/mΩ), Power Unit (W/mW), Time Unit (sec/msec), Eng Unit (Wh/mWh), Pressure Unit (KPa/Pa), Step Edit Time

Read more

2
Mar

List View

How to show the real-time information of the channels by displaying “List View”? Click “List View”, the middle choice in the bottom list of options on the BTS software. Select the data what you want to copy, and right click the interface to copy the data to Excel or other documents.

26
Feb

Reset Map

“Reset map” which means using the software to reflect the channels of the machine. How to reset map? 1.Right click on the software interface. Select “Reset Map” 2. Right click on the interface of “Set Mapping”. Select “Clear All” to delete reflecting channels which were set before on the software. 3. Right click on the interface, and select “Main/Aux channel

Read more

2
Jan

The sample of driving cycle simulation

The file of driving cycle simulation can be upload with Excel or Text and can be edited for different testing standards. we can divide into two mode:power mode with time(s/ms) and power(W/mW) columns and current mode with time(s/ms) and current(A/mA) columns in file data. The time series should be set up by accumulated way. For example, 0.5, 1, 1.5…and so

Read more

2
Jan

How to change the default unit setting in Neware software

This video shows how to change the default unit of parameters in Neware software. The default unit setting can be changed through either BTS interface or BTSDA interface. If you have more questions, please contact me with nucky@newarebattery.com

27
Dec

How to change the language form in Neware software

How to change the language in Neware software from Chinese to English. If you have more questions, please contact me with:   lulu@newarebattery.com     https://www.facebook.com/batterytester.neware