NEWARE Pack Tester Specification

CE-6001n-1500V400A-IG
System Information
| Parameter | Data |
|---|---|
| Channels | 1 |
| Channel Parallel Connection | Support max 4 channels parallel mode |
| Input Power Supply | 3PH-AC380V ±10%, 50/60 ±5Hz |
| Power Factor | ≥99% (full load) |
| THDi | ≤5% (full load) |
| Input Power | 1 cabinet, 652.2 kW |
| Input Current | 1 cabinet, 990.9 A |
| Overall System Efficiency (Max) | 96% |
| Noise | ≤75 dB |
| Size (W×D×H) | 1 cabinet, 900 × 1000 × 1850 mm |
| Weight | 1 cabinet, 700 kg |
| Power Control Module Type | IGBT |
| Input Power Wiring | Three-phase four-wire system |
| Input Protection | Anti-surge, anti-islanding, over/under-frequency & voltage, open-phase, etc. |
| Ingress Protection | IP20 |
Measurement & Output
| Parameter | Data |
|---|---|
| Voltage/Current Sampling | Four-wire (same port for charge & discharge) |
| Voltage Range | Charge 0–1500 V; Discharge 100–1500 V (min discharge 100 V) |
| Voltage Accuracy | ±0.02% of FS; 24-bit resolution |
| Current Range | 2–400 A |
| Current Accuracy (independent range) | 0.02% of FS; CV cut-off 0.05% of FS; 24-bit |
| Single-Channel Output Power | 600 kW |
| Total Output Power | 600 kW (1 channel) |
| Current Response Time (10%FS→90%FS) | ≤10 ms |
| Current Conversion Time (−90%FS→90%FS) | ≤20 ms |
| Minimum Step Time | 0.1 s |
| Input Impedance | ≥1 MΩ |
Modes & Functions
| Parameter | Data |
|---|---|
| Charge/Discharge Modes | CCC/CCD, CVC/CVD, CC-CVC/CC-CVD, CPC/CPD, CP-CVC/CP-CVD, CV-CRD, CRD, VSS, CSS |
| Cut-off Conditions | Voltage, Current, ΔTime, Capacity, −ΔV |
| Simulation | Current, Power; continuous charge/discharge switching; cut-off: Time, step line; steps: up to 1,000,000 |
| Pulse | Current, Power; min pulse 100 ms; up to 32 pulses; charge/discharge switch; cut-off: Voltage, ΔTime |
| DCIR | By calculation |
| Safety Protection | Software: set safety limits (V/I min–max, delay…); Hardware: anti-reverse, OVP/OCP/OTP |
Data & Analysis
| Parameter | Data |
|---|---|
| Step Setting Method | Form editing |
| Recording Frequency | 100 Hz (10 Hz when two AUX channels share one main channel) |
| Database | MySQL |
| Data Output | Excel, TXT (curve templates; customization supported) |
| Loop Test Range | 1–65535 |
| Steps per Loop | ≤255 |
| Loop Nesting | ≤10 |
Communication
| Parameter | Data |
|---|---|
| Host Communication | Based on TCP/IP protocol |
| Interface | Ethernet |
| Lower Computer Bandwidth | 1 M |
| Host Communication Baud | 10–100 M (adaptive) |
| Networking Mode | LAN via switches & routers |
| Communication Expansion (Optional) | CAN, RS485, BMS (DBC); supports integration with environmental chamber, water chiller, pressure fixture |
AUX (Optional)
| Parameter | Data |
|---|---|
| Temperature Channel | Type T: −70 to 260 °C; accuracy ±1 °C; resolution 0.1 °C |
| Voltage Channel | 0–5 V; accuracy ±0.05% of FS; resolution 0.1 mV |
| Usage | Bind with main V/I data; measured temperature can be used for control/protection |
Environmental Requirements
| Parameter | Data |
|---|---|
| Operating Temperature | −10 to 40 °C (within 25 ± 5 °C: accuracy guaranteed; drift 0.005% of FS/°C) |
| Storage Temperature | −20 to 50 °C |
| Operating Humidity | ≤70% RH (no condensation) |
| Storage Humidity | ≤80% RH (no condensation) |
| Altitude | <2000 m (above 2000 m: derate; every +100 m → −1 °C operating temp) |