Neware EV Battery Pack Testing Solution
Nissan Leaf

Leaf comes in five generations — ONE single solution could handle them all

Nissan LEAF Battery Pack Specifications

Nissan LEAF Battery Pack Specifications

Model / GenerationYear(s)ChemistryNominal Voltage (V)Energy (kWh)
LEAF Gen1 (ZE0)2011–2012LMO / NMC blend (AESC)≈ 36024 (gross)
LEAF Gen1.5 (AZE0)2013–2015LMO / NMC blend ("Lizard" update)≈ 36024 (gross)
LEAF Gen1.5 (AZE0)2016–2017NMC-rich (8-cell modules)≈ 36030 (gross) / ~27.7 (usable)
LEAF Gen2 (ZE1)2018–presentNMC (24×8-cell modules)≈ 350–36040 (gross) / ~37 (usable)
LEAF Gen2 e+ (ZE1)2019–presentNMC (higher energy)≈ 355–385*62 (gross) / ~56 (usable)

One Fits All

CE-6004n-400V200A-IG

CE-6004n-400V200A-IG Specifications
System Information
ParameterData
Channels4
Input Power Supply3PH-AC380V ±10%, 50/60 ±5Hz
Power Factor≥99% (full load)
THDi≤5% (full load)
Input Power2 cabinets, each 177.8 kW
Input Current2 cabinets, each 270.1 A
Overall System Efficiency (Max)94% (regenerative)
Noise≤75 dB
Size (W×D×H)Each 1350×1250×2000 mm (2 cabinets)
WeightEach 1500 kg (2 cabinets)
Power Module TypeIGBT
Input WiringThree-phase four-wire
Input ProtectionAnti-surge, anti-islanding, over/under-frequency & voltage, open-phase
Ingress ProtectionIP20
Measurement & Output
ParameterData
Sampling Wiring4-wire; shared port for charge/discharge
Voltage RangeCharge 0–400 V; Discharge 10–400 V
Voltage Accuracy±0.02% FS; 24-bit resolution
Current Range1–200 A
Current Accuracy0.05% FS (independent range); CV cut-off 0.05% FS; 24-bit
Single-Channel Power80 kW
Total Output Power320 kW (4 channels)
Current Response Time≤5 ms (10%FS→90%FS)
Current Conversion Time≤10 ms (−90%FS→90%FS)
Min Step Time0.1 s
Input Impedance≥1 MΩ
Modes & Functions
ParameterData
Charge/Discharge ModesCCC/CCD, CVC/CVD, CC-CVC/CC-CVD, CPC/CPD, CP-CVC/CP-CVD, CV-CRD, CRD, VSS, CSS
SimulationCurrent, Power; continuous charge/discharge switching; cut-offs: Time, step line; up to 1,000,000 step lines
PulseCurrent, Power; min pulse 100 ms; up to 32 pulses; charge/discharge switch; cut-offs: Voltage, ΔTime
DCIRBy calculation
ProtectionsSoftware & hardware (anti-reverse, OVP/OCP/OTP; SW limit sets: V/I min-max, delay…)
Data & Analysis
ParameterData
Step EditingForm editing
Recording Frequency100 Hz (10 Hz when two AUX share one main channel)
DatabaseMySQL
ExportExcel, TXT (curve templates; customization supported)
Loop Range1–65535 (≤255 steps per loop; nesting ≤10)
Communication
ParameterData
Host ProtocolTCP/IP (Ethernet)
Lower Computer Bandwidth1 M
Host Baud (Adaptive)10–100 M (LAN via switches/routers)
Expansion (Optional)CAN, RS485, BMS comm (DBC); env. chamber/water chiller/pressure fixture integration
Environmental Requirements
ParameterData
Operating Temperature−10 to 40 °C (accuracy guaranteed within 25 ± 5 °C; drift 0.005% FS/°C)
Storage Temperature−20 to 50 °C
Operating Humidity≤70% RH (no condensation)
Storage Humidity≤80% RH (no condensation)
Altitude<2000 m (above 2000 m: derate; every +100 m → −1 °C operating temp)

Get Expert Solutions and Quotes

Submit your request and we will respond within 2 business hours.

Who you are or the organization you represent.
Use a business email (e.g., alex@company.com). Phone can be included in the message.
0 selected
We’ll email an immediate receipt and start processing your request.
Submitted — please check your inbox for a receipt.
Submission failed — please try again.